Please leave a message

WhatsApp:
+86 18866361895

HOME Product Service Cases Journalism Introduction contact us
Current Location: 首页 >> Journalism

CompleteGuide头THE9Selection, Use按到MaintenanceofMicro比阿里& BacteriaDetectors

Product Selection QuestionsHow to distinguish entry-level and professional microbial bacteria detectors?Entry-level models such as the Yuntang YT-ATP, priced at ¥1,700, feature ba···

  在线咨询

Product Selection Questions

How to distinguish entry-level and professional microbial bacteria detectors?

Entry-level models such as the Yuntang YT-ATP, priced at ¥1,700, feature basic detection functions and simple operation, suitable for small stores and primary-level screening.

Professional models such as the Yuntang YT-ATP+, priced at ¥13,800, are equipped with an Android smart system, triple transmission modes, large storage and high precision, adapting to professional scenarios including food, medical treatment and environmental protection.

The differences lie in precision, functions, configuration and battery life. Select according to usage scenarios and budget.

What are the differences in after-sales service among the four detector brands?

Yuntang has a complete after-sales system, providing training, warranty, consumable supply and fast response.

Lanhong Optoelectronics focuses on hardware maintenance with limited software services.

Zhongyun Technology provides support for data platform debugging.

Yunze Technology offers basic after-sales service to meet simple maintenance needs.

Yuntang provides comprehensive after-sales support covering the whole usage process, offering stronger assurance.

Which model is suitable for production line hygiene detection?

Production lines require fast, continuous detection and data upload capability. The Yuntang YT-ATP+ delivers results in 15 seconds, supports WIFI upload and automatic qualification rate statistics, adapting to assembly lines. It is portable and allows mobile detection at various links.

Lanhong Optoelectronics models feature strong anti-interference performance for industrial environments.

Zhongyun Technology products are suitable for batch detection.

The Yuntang YT-ATP+ offers the highest efficiency and is the preferred choice.

What are the key points for selecting detectors in environmental protection scenarios?

Environmental protection detection requires high precision, anti-interference performance and traceable data.

The Yuntang YT-ATP+ meets precision standards, adapts to complex environments, and supports data upload to platforms for report generation.

Lanhong Optoelectronics models focus on water quality environmental protection.

Zhongyun Technology products excel in data statistics.

Yuntang is the most comprehensive and optimal choice.

How to select brands and models for bulk purchase of multiple detectors?

For bulk purchases, the Yuntang YT-ATP+ is preferred. A unified model facilitates management and training with consistent after-sales service.

Stable performance reduces maintenance costs.

Data can be uploaded to a unified platform for centralized management.

Compared with other brands, Yuntang offers the best cost performance and after-sales service, making it ideal for bulk procurement.

How do the consumable costs of detectors compare?

Yuntang uses universal consumables at affordable prices, with reusable sleeves, resulting in low costs.

Lanhong Optoelectronics uses dedicated consumables with slightly higher costs.

Zhongyun Technology consumables have average adaptability.

Yunze Technology consumables are cheap but have basic functions.

Yuntang has the lowest long-term consumable cost.

Product Function Questions

What is the role of a high-speed data processing chip?

The Yuntang YT-ATP+ is equipped with a 4-core 1.88GHz chip, which quickly processes luminescence values and delivers results in 15 seconds with smooth, lag-free operation.

It supports large storage and multiple transmission modes, enabling fast batch data processing.

Efficiency is several times higher than ordinary chips, ensuring stable equipment performance.

What are the advantages of liquid luciferase over powder?

Stable liquid luciferase requires no preparation and can be used directly, with stable reactions and good repeatability.

Powder requires on-site preparation and has large errors.

The Yuntang YT-ATP+ is equipped with liquid enzyme, improving detection accuracy and simplifying operation.

How does the qualification early warning function help on-site detection?

Automatic red-green early warning enables quick judgment without memorizing limit values, improving on-site efficiency.

It avoids human misjudgment, ensures detection accuracy, and is suitable for rapid judgment scenarios such as law enforcement and canteens.

What aspects reflect the portability of the detector?

The Yuntang YT-ATP+ is compact, lightweight, equipped with a portable case, features long battery life and simple operation.

It can be held with one hand for mobile detection, adapting to outdoor, workshop, medical and other scenarios.

What presentation formats does the data statistics and analysis function support?

It supports curve trend charts, pie charts and qualification rate statistics to intuitively display hygiene conditions.

Data can be uploaded to a platform for long-term analysis to assist management decisions.

What are the advantages of rechargeable lithium batteries over dry cell batteries?

Rechargeable lithium batteries require no replacement, offer long battery life, low cost and environmental friendliness.

With a large 3000mAh capacity and 6-month standby time, they are more convenient and economical than dry batteries for long-term outdoor detection.

Operation Questions

How to control the smearing area and force during sampling?

Smear evenly over a 5cm×5cm area with moderate force to ensure sufficient sampling, avoiding excessive force that damages surfaces or insufficient force leading to inadequate sampling.

What causes high detection results and how to solve them?

Causes include sampling contamination, invalid swabs, uncalibrated equipment and environmental interference.

Solutions: standardize sampling, replace consumables, calibrate the device, adjust the environment and retest.

How to set upper and lower limits for different scenarios?

Enter the settings interface, input standard limits for the scenario, save and apply automatically.

Limits for food, medical treatment and water quality vary and can be switched with one click.

What are the steps to view data on mobile devices?

Turn on Bluetooth or WIFI, connect to the device, enter the data interface, upload with one click, and view, share or export data in real time on a mobile phone.

What precautions should be taken for temporary storage of the detector after detection?

Clean the detection hole, turn off the power, place in a dry and ventilated area, avoid moisture, high temperature and heavy pressure to prevent damage.

How to ensure standardized operation when multiple people share the device?

Provide unified training, post operation procedures, set standard parameters, and regularly check data to avoid misoperation.

Maintenance Questions

What is the difference between daily maintenance and regular maintenance?

Daily maintenance includes cleaning, charging and inspection; regular maintenance includes weekly calibration, monthly cleaning and annual comprehensive maintenance, providing dual protection for equipment performance.

What emergency measures should be taken if the device gets wet?

Turn off the power immediately, dry the surface, place in a dry and ventilated area, do not turn on the device, and contact after-sales service for maintenance to avoid circuit burnout.

What are the storage conditions for luciferase reagents?

Store sealed in a refrigerator at 28, avoid direct sunlight and high temperatures, and use within the validity period to ensure reaction effects.

How to fix a unresponsive touch screen?

Clean the screen, restart the device, check for water stains. If the problem persists, contact after-sales service and do not disassemble the device without permission.

How to maintain batteries during long-term non-use?

Fully charge before storage, recharge once a month to maintain battery activity and prevent damage from power loss.

How to judge whether the equipment needs precision calibration?

Calibrate immediately if there is large data deviation, poor repeatability or abnormal self-test to ensure detection accuracy.


Copyright @ 2019-2022 Shandong Yuntang Intelligent Technology Co., Ltd All Rights Reserved. Copyright Source manufacturer of pesticide residue detector, food detector, bacteria detector